News & Events


Related Pages

BUNKER FLASH

High Catfines Found in the ARA Region

As issued on 12 July 2024

Findings & Insights:

From the period of 08 May 2024 to 05 July 2024, Maritec Pte Ltd (hereafter referred to as CTI-Maritec) tested twenty-two samples representing both HSFO and VLSFO deliveries from various suppliers in the Amsterdam-Rotterdam-Antwerp (ARA) region, which showed Aluminium and Silicon (Al+Si) concentrations ranging from 40 mg/Kg up to 177 mg/kg.

Out of the twenty-two samples, CTI-Maritec found Aluminium and Silicon (Al+Si) concentrations in two samples to be above 100 mg/Kg and in one sample at 68 mg/Kg level.

While the rest of the samples fell within the specifications of ISO8217:2005 (80 ppm) and even within the ISO8217:2010/2017 specification (including permitted limits of 72 PPM as per ISO4259 for a single test result), the Catfines content were still considered at high levels. Many of these samples were also found to have high density, high TSP and high CCAI.

Aluminium and Silicon are main classes of abrasive solids found in fuels. High levels of abrasive particles at the engine inlet may lead to abnormal wear and tear of the fuel system components, piston rings and cylinder liners. To control the maximum amount of catalyst fines delivered to the engine, many engine builders specify a maximum limit of 15 mg/kg of Aluminium plus Silicon at engine inlet.

An efficiently operating fuel purification system is the main way of removing these particles. Measuring the fuel’s Aluminium and Silicon concentrations before and after centrifuge provides an indication of the efficiency of the system in removing catalyst fines.

Due to relatively high TSP, fuels might generate increased sludge formation, especially at the Purifiers and filters. Due to high CCAI, fuels might have ignition and combustion related issues.

Our Recommendations:

CTI-Maritec recommends collecting samples from within the fuel system at points such as the fuel oil tank transfer pump, before and after centrifuge, service tank and after filter samples to check the fuel cleaning efficiency.

This document, however, does not reflect on the overall quality of fuel being supplied in ARA region, if you intend to bunker at this region please request for a Certificate of Quality prior to loading.

CTI-Maritec can assist you with further information on quality of bunkers tested in different regions. If you require any other information or assistance do not hesitate to Contact us.

 

 

Get in touch

If you have any questions or comments please don't hesitate to contact us